finger bandage 300x271 Straight Suture SafetyHopefully you are using ultrasound to guide your insertion of central venous catheters. Once they are in, you still have to suture them at some point. Straight suture needles are often used to secure arterial and venous catheters to the skin. These types of suture needles have been demonstrated to be more dangerous than curved or blunt suture needles, with up to seven times higher rate of injury for health care workers. By utilizing the plastic needle sheath present in most central venous line kits as a “thimble,” counter pressure and skin puncture may be achieved without bringing the fingers near the sharp end of the suture. Here’s an image from Bret Nelson’s article on the technique.

Straight Sutre Safe 500x213 Straight Suture Safety

Panel A shows counter-pressure being applied with the cap to direct the tip of the needle. Panel B shows the needle tip safely sheathed within the cap.

The video below demonstrates this technique in real time:

 

Safety technique for straight suture needle from Sinai EM Ultrasound on Vimeo.

 

Other authors have illustrated alternative techniques to reduce the risk of self-injury when using straight suture needles.  Steven Bauer uses a 5-mL syringe to ensconce the emerging straight needle. This can provide even more distance, and he also uses it to guide tying an ‘air knot’ when needed!

syringe needle cap Bauer Straight Suture Safety

Haney Mallemat has just posted a video where he demonstrates using the paper envelope the suture is packaged in to distance the needle tip from your fingers.

Keep in mind NONE of these techniques has been studied- there is no evidence that they reduce needlesticks. We DO know that using curved, blunt-tip suture needles used with needle drivers and forceps is safer than using straight sutures. Whichever method you use please be careful!

References

  • Nelson BP. Making straight suture needles a little safer: a technique to keep fingers from harm’s way. J Emerg Med. 2008 Feb; 34(2):195-7. Epub 2007 Oct 1. (PMID: 18282537)
  • Bauer S, Tauferner D, Carlson D. Improving straight needle safety: an alternate method. J Emerg Med. 2011 Jul; 41(1):e19-20. Epub 2009 Sep 17. (PMID: 19765943)
  • Centers for Disease Control and Prevention. Evaluation of blunt suture needles in preventing percutaneous injuries among healthcare workers during gynecologic surgical procedures—New York City, March 1993–June 1994. MMWR Morb Mortal Wkly Rep 1997;46:25–9. (PMID: 9011779)
  • Edlich RF, Wind TC, Hill LG, Thacker JG, McGregor W. Reducing accidental injuries during surgery. J Long Term Eff Med Implants 2003;13:1–10. (PMID: 12825744)

 

Top 3 Articles: Ultrasound guided Central Venous Catheter Insertion

ij setup2 Top 3 Articles: Ultrasound guided Central Venous Catheter InsertionThe literature for using ultrasound guidance in placing a central venous line is robust. There are many articles espousing the benefits of ultrasound guidance: reduced number of attempts, reduced complication rate, increased first pass success rate. So, it is indeed difficult to narrow down to a finger count of 3 articles. But if one were to spend time reading just 3 articles that define the topic, these 3 should be as good as any. Continue reading

Journal Club – December 2009

Screen shot 2010 01 05 at 12.32.39 PM Journal Club   December 2009This month we reviewed two articles on ultrasound guidance for central access.  The first of these was an instructive case series by Mike Blaivas — Video Analysis of Accidental Cannulation with Dynamic Ultrasound Guidance for Central Venous Access: Michael Blaivas: J Ultrasound Med 2009; 28:1239–1244.

At the author’s institution, a continuous recording of ultrasound guidance is usually obtained for each central line placement.  This allowed him to perform a retrospective analysis of the video recording of 6 cases in which arterial cannulation occurred despite the use of ultrasound.   Arterial cannulation in these patients led to serious complication in 4 patients, airway compromise in one, and to death in the sixth.   The findings remind us of what we ought to already know and Dr. Blaivas offers suggestions to decrease the likelihood of these outcomes.

What we know:

  • Hypotensive patients are more likely to have collapsible veins – increasing the likelihood of puncturing the posterior wall of the vessel.
  • Hypotensive patients  less likely to have the strongly pulsatile arterial flow – rendering this an inadequate measure of confirmation of venous cannulation.
  • Hypoxic patients are more likely to have darker arterial blood – making this another inadequate marker of venous cannulation.

The author reminds us that short axis placement may be misleading.  That is, the hyperechoic part of the needle you are imaging inside a vein may actually be the midportion of your needle rather than the tip.  The tip may actually deeper, within unseen structures such as the carotid artery.  He concludes that it may be superior to cannulate the central vein using the long view, or at least to confirm placement of the guidewire in long view to confirm venous placement before dilation.

Would this publication change our practice? This report gave us all food for thought as our current policy regarding prevention of arterial cannulation includes measures which are largely post-dilation.  We agreed that there is little downside to checking the placement of the guidewire in long view prior to dilation.  Coupled with manometry prior to dilation, long view provides the best evidence that your placement is correct.

——————————————————————————————————————————————————–

Screen shot 2010 01 05 at 12.32.30 PM Journal Club   December 2009Thanks to Eduardo LaCalle for his excellently summary and critique of the second article — Ultrasound localization of central vein catheter and detection of postprocedural pneumothorax: An alternative to chest radiograph: Vezzani et. al. : Crit Care Med 2010 Vol. 38, No. 2.

Dr. Vezzani, et. al., set out to look at confirmation of line placement via another route — CXR vs. US.  This was a prospective diagnostic study performed in the ICU of a large hospital (1200 beds) in Parma, Italy. They looked at all ICU patients older than 18 over 6 months. What they did was to place central line by landmark technique. Then each patient had ultrasound, including contrast enhanced ultrasound (CEUS) as well a cxr. The contrast was provided by agitated saline (9cc saline with 1 cc air). These studies were performed by a single sonographer. Appropriate SVC placement was indicated by laminar flow of bubbles seen in the RV on CEUS via subxyphoid view. RA/IVC placement was indicated by the tip seen in the RA or turbulent flow implying that the agitated saline was being infused directly into the RA. IJ placement was implied by a >2 second delay to appearance of bubbles during CEUS. In addition US was used to check for PTX.

They had 111 cases. 99 were not technically limited. 34 complications were noted on ultrasound vs. 30 on CXR. Ultrasound noted 25 RA placements, 4 IJ placements and 4 Pneumothoraces. CXR noted 24 RA, 4 IJ placements and 2 Pneumothoraces. The authors concluded that CEUS and CXR are at least equivalent and us should replace cxr after central line placement to r/o ptx and confirm tip position.

Would this publication change our practice? Well there are some limitations to this study that give pause. First of all, the CEUS exams were performed by a single sonographer, the first author of the study. This suggests that technical proficiency may play a significant role here – similar results may not be easily achievable by your average EP.   On the other hand, the gold standard for confirming catheter placement or pneumothorax in this study, CXR, is known not to be without fail .  I would be loathe to drop the CXR confirmation based on this single study.  However, there is clearly a role for ultrasound in line confirmation and it probably ought to be added to CXR, especially to look for pneumothorax.